Basic Info.
Model NO.
CJ-AT
Trademark
Changjin
Origin
Shanghai
HS Code
76061199
Production Capacity
50000ton/Year
Product Description
Product Details:
Our customers are from all over the world, we welcome customers to our company to visit and communicate.
For our products' quality and service's level has been a great help.
FAQ:
Q1:How long time is the shortest delivery?
A1:For stock material,the delivery time is just 3-5 working days.
And for customized product,it will takes 25-35 working days based on different size and quantity.
Q2:Can you supply the sample?Does it free or not?
A2:For partial materials,we can supply the sample free(without the freight charge).
If you want to know more details,please contact our sales online.
Q3:What's the terms of payment?
A3:We can accept T/T,100% irrevocable LC at sight,Western Union,etc,
Q4:How to ensure the quality?
A4: We can supply QC,such as MTC,SGS, UT Certificate,etc.
Besides,we have Trade Assurance Amount from Alibaba Group.
If our quality is unapproved,we need and will refund full payment to customers
Q4.How can we get your price ?
We need below information to quote for you:
1. Product Name
2. Standard
3. Material Grade (Chemical Composition)
4. Dimension
5. Quantity
6. The Drawing for Special Parts
NO | China(GB/T) | American AA | Japan JIS | German CORUS | Britain DIN | France NF | Russian ГOCT | India IS | ISO | EN |
1 | 2A01 | BД17/1170 | ||||||||
2 | GB/T3190-1996 | ГOCT4785-1974 | ||||||||
3 | 2A06 | Д16/1190 | ||||||||
4 | GB/T3190-1996 | ГOCT4785-1974 | ||||||||
5 | 2A10 | B65/1165 | ||||||||
6 | GB/T3190-1996 | ГOCT4785-1974 | ||||||||
7 | 2A11 | 2017/A92017 | A2017 | Д1/1110 | 24534 | AL Cu4MgSi | ||||
8 | GB/T3190-1996 | AA/UNS | JIS H4000-1999 JIS H4040-1999 | ГOCT4785-1974 | IS733-2001 IS737-2001 | ISO 209.1-1989 | ||||
9 | 2A11 | 2024 | A2024 | AICuMg2/3.1355 | 2024(A-U4G1) | Д16/1160 | 24530 | AICu4Mg1 | EN AW-2024/AI Cu4Mg1 | |
10 | GB/T3190-1996 | AA | JIS H4000-1999 JIS H4040-1999 | DIN 1725-1-1986 | NF A50-411 NF A50-451 | ГOCT4785-1974 | IS 5902 | ISO 209.1-1989 | EN 573-3-1994 | |
11 | 2A16 | 2219/A92219 | A2219 | Д20/1201 | AICu6Mn | EN AW-2219/AI Cu6Mn | ||||
12 | GB/T3190-1996 | AA/UNS | JIS H4000-1999 JIS H4040-1999 | ГOCT4785-1974 | ISO209.1-1989 | EN 573-3-1994 | ||||
13 | 2A70 | 2618/A92618 | A2618 | AK4-1/1141 | ||||||
14 | GB/T3190-1996 | AA/UNS | JIS H4140-1988 | ГOCT4785-1974 | ||||||
15 | 2A80 | A2N01 | AK4/1140 | |||||||
16 | GB/T3190-1996 | JIS H4140-1988 | ГOCT4785-1974 | |||||||
17 | 2A90 | 2018/A92018 | A2018 | AK2/1120 | ||||||
18 | GB/T3190-1996 | AA/UNS | JIS H4140-1988 | ГOCT4785-1974 | ||||||
19 | 2011 | 2011/A92011 | A2011 | AICuBiPb/3.1655 | 2011(FC1) | 2011(A-U5PbBi) | ~Д1/1110 | AI Cu6BiPb | EN AW-2011/AI Cu6BiPb | |
20 | GB/T3190-1996 | AA/UNS | JIS H4040-1999 JIS H4080-1999 | DIN 1725-1-1986 | BS 1470-1988 | NF 50-411 | ГOCT4785-1974 | ISO 209.1-1989 | EN 573-3-1994 | |
21 | 2014 | 2014/A92014 | A2014 | AICuSiMn/3.1655 | 2014(H15) | 2014(A-U4SG) | AK8/1380 | 24345 | AI Cu4SiMg | EN AW-2014/AI Cu4SiMg |
22 | GB/T3190-1996 | AA/UNS | JIS H4000-1999 JIS H4040-1999 | DIN 1725-1-1986 | BS 14710-1988 | NF A50-411 NF A50-451 | ГOCT4785-1974 | IS733-2001 IS737-2001 | ISO209.1-1989 | EN 573-3-1994 |
23 | 2014A | 2014A | A2014A | AI Cu4SiMg(A) | EN AW-2014A/AI Cu4SiMg(A) | |||||
24 | GB/T3190-1996 | AA | JIS H4100-1999 JIS H4040-1999 | ISO 209.1-1989 | EN 573-3-1994 | |||||
25 | 2017A | 2017A/A92017 | A2017A | AICuMg1/3.1325 | 2017A(A-U4G) | AK21/1120 | 24534 | AI Cu4MgSi(A) | EN AW-2017A/AI Cu4MgSi(A) | |
26 | GB/T3190-1996 | AA/UNS | JIS H4040-1999 JIS H4080-1999 | DIN 1725-1-1986 | NF A50-411 NF A50-451 | ГOCT4785-1974 | IS733-2001 IS737-2001 | ISO 209.1-1989 | EN 573-3-1994 | |
27 | 2024 | 2024/A92024 | A2024 | AICuMg2/3.1355 | 2024(A-U4G1) | Д16/1160 | 24530 | AI Cu4Mg1 | EN AW-2024/AI Cu4Mg1 | |
28 | GB/T3190-1996 | AA/UNS | JIS H4100-1999 JIS H4040-1999 | DIN 1725-1-1986 | NF A50-411 NF A50-451 | ГOCT47785-1974 | ГOCT47785-1974 | IS 739-2001 | EN 573-3-1994 | |
29 | 2124 | 2124/A92124 | Д16Л/1161 | EN AW-2124/AI Cu4Mg1(A) | ||||||
30 | GB/T3190-1996 | AA/UNS | ГOCT4785-1974 | EN 573-3-1994 | ||||||
31 | 2117 | 2117/A92117 | A2117 | AICu2.5Mg0.5/3.1305 | 2117(A-U2G) | AI Cu2.5Mg | EN AW-2117/AI Cu2.5Mg | |||
32 | GB/T3190-1996 | AA/UNS | JIS H4040-1999 | DIN 1725-1-1986 | NFA50-451 | ISO 209.1-1989 | EN 573-3-1994 | |||
33 | 2214 | 2214/A92214 | ~ AK8/1380 | EN AW-2214/AI Cu4SiMg(B) | ||||||
34 | GB/T3190-1996 | AA/UNS | ГOCT4785-1974 | EN 573-3-1994 | ||||||
35 | 2218 | 2218/A92218 | A2218 | 2218(A-U4N) | ||||||
36 | GB/T3190-1996 | AA/UNS | JIS H4140-1988 | NF 50-411 | ||||||
37 | 2618 | 2618/A92618 | A2618 | AK4-1/1141 | ||||||
38 | GB/T 3190-1996 | AA/UNS | JIS H4140-1988 | ГOCT 4785-1974 | ||||||
39 | 2001/A92001 | 2001(A-U6MT) | EN AW-2001/AI Cu5.5MgMn | |||||||
40 | AA/UNS | NF A50-101 | EN 573-3-1994 | |||||||
41 | 2007/A92007 | AICuMgPb/3.1645 | EN AW-2007/AI Cu4PbMgMn | |||||||
42 | AA/UNS | DIN 1725-1-1986 | EN 573-3-1994 | |||||||
43 | 5A02(LF2) | 5052/A95052 | A5052 | AIMg2.5/3.3523 | 5052(NS4) | 5052(A-G2.5C) | AMr2/1520 | AI Mg2.5 | EN AW-5052/AI Mg2.5 | |
44 | GB/T 3190-1996 | AA/UNS | JIS H4040-1999 JIS H4100-1988 | DIN 1725.1-1986/W-Nr. | BS 1470-1988 | NF A50-411 NF A50-451 | ГOCT 4785-1974 | ISO 209.1-1989 | EN 573-3-1994 | |
45 | 5A03(LF3) | 5154/A95154 | A5154 | 5154A(NS5) | 5154A(A-G3C) | AMr3/1530 | AI Mg3.5 | EN AW-5154A/AI Mg3.5(A) | ||
46 | GB/T 3190-1996 | AA/UNS | JIS H4000-1999 | BS 1470-1988 | NF A50-411 NF A50-451 | ГOCT 4785-1974 | ISO 209.1-1989 | EN 573-3-1994 | ||
47 | 5A05(LF5) | 5456/A95456 | ~A5056 | AIMg5/3.3555 | 5056(A56S) | ~AMr5/1550 | AI Mg5Mn1 | ~EN AW-5019/AI Mg5 | ||
48 | GB/T 3190-1996 | AA/UNS | JIS H4040-1999 JIS H4080-1999 | DIN 1725.1-1986/W-Nr. | BS 1470-1988 | ГOCT 4785-1974 | ISO 209.1-1989 | EN 573-3-1994 | ||
49 | 5A06(LF6) | A5005 | AMr6/1560 | |||||||
50 | GB/T 3190-1996 | JIS H4040-1999 JIS H4100-1988 | ГOCT 4785-1974 | |||||||
51 | 5005 | 5005/A95005 | A5005 | 5005(N41) | 5005(A-G0.6) | AMr1/1510 | 51000-A | AI Mg1(B) | EN AW-5005/AI Mg1(B) | |
52 | GB/T 3190-1996 | AA/UNS | JIS H4040-1999 JIS H4100-1988 | BS 1470-1988 | NF A50-411 NF A50-451 | ГOCT 4785-1974 | IS733-2001 IS737-2001 | ISO 209.1-1989 | EN 573-3-1994 | |
53 | 5019 | 5019/A95019 | AIMg5/3.3555 | 5019(NB6) | AMr5/1550 | EN AW-5019/AI Mg5 | ||||
54 | GB/T 3190-1996 | AA/UNS | DIN 1725.1-1986/W-Nr. | BS 1470-1988 | ГOCT 4785-1974 | EN 573-3-1994 | ||||
55 | 5050 | 5050/A95050 | AIMg1.5/3.3316 | 5050(2L44) | 5050(A-G1.5) | AMr1/1510 | 51000-B | AI Mg1.5(C) | EN AW-5050/AI Mg1.5(C) | |
56 | GB/T 3190-1996 | AA/UNS | DIN 1725.1-1986/W-N | BS 1470-1988 | NF A50-451 | ГOCT 4785-1974 | IS733-2001 IS737-2001 | ISO 209.1-1989 | EN 573-3-1994 | |
57 | 5052 | 5052/A95052 | A5052 | AIMg2.5/3.3523 | 5052(2155) | 5052(A-G2.5C) | AMr2/1520 | AI Mg2.5 | EN AW-5052/AI Mg2.5 | |
58 | GB/T 3190-1996 | AA/UNS | JIS H4000-1988 | DIN 1725.1-1986/W-Nr. | BS "L" | NF A50-411 NF A50-451 | ГOCT 4785-1974 | ISO 209.1-1989 | EN 573-3-1994 | |
59 | 5056(LF5-1) | 5056A95056 | A5056 | AIMg5/3.3555 | 5056(NG6/2L58) | AMr5/1550 | AI Mg5Cr | EN AW-5056A/AI Mg5 | ||
60 | GB/T 3190-1996 | AA/UNS | JIS H4040-1999 JIS H4080-1999 | DIN 1725.1-1986/W-Nr. | BS 1470-1988/BS "L" | ГOCT 4785-1974 | ISO 209.1-1989 | EN 573-3-1994 | ||
61 | 5083 | 5083/A95083 | A5083 | AIMg4.5Mn/3.3547 | 5083(NT8) | 5083(A-G4.5MC) | 54300 | AI Mg4.5Mn0.7 | EN AW-5083/AI Mg4.5Mn0.7 | |
62 | GB/T 3190-1996 | AA/UNS | JIS H4040-1999 JIS H4080-1999 | DIN 1725.1-1986/W-Nr. | BS 1470-1988 | NF A50-411 NF A50-451 | IS733-2001 IS737-2001 | ISO 209.1-1989 | EN 573-3-1994 | |
63 | 5086 | 5086/A95086 | A5086 | AIMg4Mn/3.3545 | 5086(A-G4MC) | AMr4/1540 | AI Mg4 | EN AW-5086/AI Mg4 | ||
64 | GB/T 3190-1996 | AA/UNS | JIS H4000-1999 JIS H4080-1999 | DIN 1725.1-1986/W-Nr. | NF A50-411 NF A50-451 | ГOCT 4785-1974 | ISO 209.1-1989 | EN 573-3-1994 | ||
65 | 5154 | 5154/A95154 | A5154 | 5154(A-G3C) | AMr3/1530 | AI Mg3.5 | ||||
66 | GB/T 3190-1996 | AA/UNS | JIS H4040-1999 JIS H4100-1988 | NF A50-411 NF A50-451 | ГOCT 4785-1974 | ISO 209.1-1989 | ||||
67 | 5154A | 5154A | 5154A(NS5) | 53000 | AI Mg3.5(A) | EN AW-5154A/AI Mg3.5(A) | ||||
68 | GB/T 3190-1996 | AA | BS 1470-1988 | IS733-2001 IS737-2001 | ISO 209.1-1989 | EN 573-3-1994 | ||||
69 | 5182 | 5182/A95182 | A5182 | AIMg5Mn/3.3549 | 5182(A-G4.5M) | EN AW-5182/AI Mg4.5Mn0.4 | ||||
70 | GB/T 3190-1996 | AA/UNS | JIS H4000-1999 | DIN 1725.1-1986/W-Nr. | NF A50-481 | EN 573-3-1994 | ||||
71 | 5183 | 5183/A95183 | A5183 | AIMg4.5Mn/3.3547 | 5183(NG8) | (~A-G4.5MC) | AMr4.5 | AI Mg4.5Mn0.7(A) | EN AW-5183/AI Mg4.5Mn0.7(A) | |
72 | (GB/T) | AA | JIS | CORUS | DIN | NF | ГOCT | IS | ISO | EN |
73 | 5251 | 5251/A95251 | AIMg2Mn0.3/3.3525 | 251(N4/3L80) 5 | 5251(A-G2M) | AMr2/1520 | 52000 | AI Mg2 | EN AW-5251/AI Mg2 | |
74 | GB/T 3190-1996 | AA/UNS | DIN 1725.1-1986/W-Nr. | BS 1470-1988/BS "L" | NF A50-411 NF A50-451 | ГOCT 4785-1974 | IS733-2001 IS737-2001 | ISO 209.1-1989 | EN 573-3-1994 | |
75 | 5356 | 5356/A95356 | A5356 | AI Mg5Cr(A) | EN AW-5356/AI Mg5Cr(A) | |||||
76 | GB/T 3190-1996 | AA/UNS | JIS Z3232-1986 | ISO 209.1-1989 | EN 573-3-1994 | |||||
77 | 5454 | 5454/A95454 | A5454 | AIMg2.7Mn/3.3537 | 5454(N51) | 5454(A-G2.5MC) | AI Mg3Mn | EN AW-5454/AI Mg3Mn | ||
78 | GB/T 3190-1996 | AA/UNS | JIS H4040-1999 JIS H4100-1999 | DIN 1725.1-1986/W-Nr. | BS 1470-1988 | NF A50-411 NF A50-451 | ISO 209.1-1989 | EN 573-3-1994 | ||
79 | 5456 | 5456/A5456 | ~AMr5/1550 | AI Mg5Mn1 | ~EN AW-5456A/AI Mg5Mn1(A) | |||||
80 | GB/T 3190-1996 | AA/UNS | ГOCT 4785-1974 | ISO 209.1-1989 | EN 573-3-1994 | |||||
81 | 5554 | 5554/A95554 | A5554 | 5554(N52) | AI Mg3Mn(A) | EN AW-5554/AI Mg3Mn(A) | ||||
82 | GB/T 3190-1996 | AA/UNS | JIS H4160-1994 | BS 1470-1988 | ISO 209.1-1989 | EN 573-3-1994 | ||||
83 | 5049/A95049 | AIMg2Mn0.8/3.3527 | 5049 | EN AW-5049/AI Mg2Mn0.8 | ||||||
84 | AA/UNS | DIN 1725.1-1986/W-Nr. | NF A50-451 | EN 573-3-1994 | ||||||
85 | 5556/A95556 | A5556 | 5556(N61) | 55380 | EN AW-5556A/AI Mg5Mn | |||||
86 | AA/UNS | JIS H33263-1992 | BS 1470-1988 | IS733-2001 IS737-2001 | EN 573-3-1994 | |||||
87 | 5654/A95654 | A5654 | EN AW-5654/AI Mg3.5Cr | |||||||
88 | AA/UNS | JIS H4000-1988 | EN 573-3-1994 | |||||||
89 | 6A02(LD2) | ~6151 | A6165 | AISiMgCu/3.3214 | AB/1340 | |||||
90 | GB/T 3190-1996 | AA | JIS H4040-1999 JIS H4100-1999 | DIN 1725.1-1986/W-Nr. | ГOCT 4785-1974 | |||||
91 | 6005 | 6005/A96005 | AI SiMg | EN AW-6005/AI SiMg | ||||||
92 | GB/T 3190-1996 | AA/UNS | ISO 209.1-1989 | EN 573-3-1994 | ||||||
93 | 6005A | 6005A | AIMgSi0.7/3.3210 | AI SiMg(A) | EN AW-6005A/AI SiMg(A) | |||||
94 | GB/T 3190-1996 | AA | DIN 1725.1-1986/W-Nr. | ISO 209.1-1989 | EN 573-3-1994 | |||||
95 | 6082 | 6082/A96082 | AIMgSi1/3.2315 | 6082(A-SGM0.7) | AД35/1350 | 64430 | AI SiMgMn | EN AW-6082/AI SiMgMn | ||
96 | GB/T 3190-1996 | AA/UNS | DIN 1725.1-1986/W-Nr. | NF A50-411 NF A50-451 | ГOCT 4785-1974 | IS733-2001 IS737-2001 | ISO 209.1-1989 | EN 573-3-1994 | ||
97 | 6351 | 6351/A96351 | AB/1340 | AI SiMg0.5Mn | EN AW-6351/AI SiMg0.5Mn | |||||
98 | GB/T 3190-1996 | AA/UNS | ГOCT 4785-1974 | ISO 209.1-1989 | EN 573-3-1994 | |||||
99 | 6060 | 6060/A96060 | AIMgSi0.5/3.3206 | 6060(A-GS) | AI MgSi | EN AW-6060/AI MgSi | ||||
100 | GB/T 3190-1996 | AA/UNS | DIN 1725.1-1986/W-Nr. | NF A50-411 | ISO 209.1-1989 | EN 573-3-1994 | ||||
101 | 6061(LD30) | 6061/A96061 | A6061 | AIMgSi1Cu/3.3211 | 6061(N20/H20) | 6061(A-GSUC) | AД33/1330 | 65032 | AI Mg1SiCu | EN AW-6061/AI Mg1SiCu |
102 | GB/T 3190-1996 | AA/UNS | JIS H4040-1999 JIS H4000-1999 | DIN 1725.1-1986/W-Nr. | BS 1470-1988 | NF A50-411 NF A50-451 | ГOCT 4785-1974 | IS733-2001 IS737-2001 | ISO 209.1-1989 | EN 573-3-1994 |
103 | 6063(LD31) | 6063/A96063 | A6063 | 6063(HT9) | (~A-GS) | AД31/1310 | 63400 | AI Mg0.7Si | EN AW-6063/AI Mg0.7Si | |
104 | GB/T 3190-1996 | AA/UNS | JIS H4040-1999 JIS H4100-1999 | BS 1470-1988 | NF A50-411 NF A50-451 | ГOCT 4785-1974 | IS733-2001 IS737-2001 | ISO 209.1-1989 | EN 573-3-1994 | |
105 | 6063A | 6063A | AI Mg0.7Si(A) | EN AW-6063A/AI Mg0.7Si(A) | ||||||
106 | GB/T 3190-1996 | AA | ISO 209.1-1989 | EN 573-3-1994 | ||||||
107 | 6101 | 6101/A96101 | A6101 | ~E-AIMgSi0.5/3.3207 | E-AI MgSi | EN AW-6101/E-AI MgSi | ||||
108 | GB/T 3190-1996 | AA/UNS | JIS H4180-1990 | DIN 1725.1-1986/W-Nr. | ISO 209.1-1989 | EN 573-3-1994 | ||||
109 | 6101A | 6101A | 6101A(E91E) | E-AI MgSi(A) | EN AW-6101A/E-AI MgSi(A) | |||||
110 | GB/T 3190-1996 | AA | BS 2898-1988 | ISO 209.1-1989 | EN 573-3-1994 | |||||
111 | 6081/A96081 | 6081(A-SGM0.3) | EN AW-6081/AI Si0.9MgMn | |||||||
112 | AA/UNS | NF A50-451 | EN 573-3-1994 | |||||||
113 | 6262/A96262 | 6262 | AI Mg1SiPb | EN AW-6262/AI Mg1SiPb | ||||||
114 | AA/UNS | BS 2898-1988 | ISO 209.1-1989 | EN 573-3-1994 | ||||||
115 | 6463/A96463 | 6463(91E/E6) | EN AW-6463/AI Mg0.7Si(B) | |||||||
116 | AA/UNS | BS 1474-1988 | EN 573-3-1994 | |||||||
117 | 7A01(LB1) | 7072/A97072 | A7072 | AI Zn1/3.4415 | Aц1 | EN AW-7072/AI Zn1 | ||||
118 | GB/T 3190-1996 | AA/UNS | JIS H4000-1999 | DIN 1725.1-1986/W-Nr. | ГOCT 4785-1974 | EN 573-3-1994 | ||||
119 | 7A03(LC3) | B94/1940 | ||||||||
120 | GB/T 3190-1996 | ГOCT 4785-1974 | ||||||||
121 | 7A04(LC4) | 7010/A97010 | 7010 | B95/1950 | AI Zn6MgCu | EN AW-7010/AI Zn6MgCu | ||||
122 | GB/T 3190-1996 | AA/UNS | BS 1470-1988 | ГOCT 4785-1974 | ISO 209.1-1989 | EN 573-3-1994 | ||||
123 | 7A05(705) | 7005/A97005 | A7N01 | AцM | 74530 | AI Zn4.5Mg1.5Mn | EN AW-7005/AI Zn4.5Mg1.5Mn | |||
124 | GB/T 3190-1996 | AA/UNS | JIS H4080-1999 JIS H4000-1999 | ГOCT 4785-1974 | IS733-2001 IS737-2001 | ISO 209.1-1989 | EN 573-3-1994 | |||
125 | 7A10(LC10) | ~7079 | ||||||||
126 | GB/T 3190-1996 | AA | ||||||||
127 | 7A52(LC525210) | ~7017/A97017 | ≈1925 | |||||||
128 | GB/T 3190-1996 | AA/UNS | ГOCT 4785-1974 | |||||||
129 | 7003(LC12) | 7003/A97003 | A7003 | EN AW-7003/AI Zn6Mg0.8Zr | ||||||
130 | GB/T 3190-1996 | AA/UNS | JIS H4040-1999 JIS H4100-1999 | EN 573-3-1994 | ||||||
131 | 7005 | 7005/A97005 | A7N01 | 74530 | AI Zn4.5Mg1.5Mn | EN AW-7005/AI Zn4.5Mg1.5Mn | ||||
132 | GB/T 3190-1996 | AA/UNS | JIS H4080-1999 JIS H4000-1999 | IS733-2001 IS737-2001 | ISO 209.1-1989 | EN 573-3-1994 | ||||
133 | 7020 | 7020/A9020 | AIZn4.5Mg1/3.4335 | 7020(A-Z5G) | ~1925C | AI Zn4.5Mg1 | EN AW-7020/AI Zn4.5Mg1 | |||
134 | GB/T 3190-1996 | AA/UNS | DIN 1725.1-1986/W-Nr. | NF A50-411 NF A50-451 | ГOCT 4785-1974 | ISO 209.1-1989 | EN 573-3-1994 | |||
135 | 7022 | 7022/A97022 | AIZn1MgCu0.5/3.4345 | EN AW-7022/AI Zn5Mg3Cu | ||||||
136 | GB/T 3190-1996 | AA/UNS | DIN 1725.1-1986/W-Nr. | EN 573-3-1994 | ||||||
137 | 7050 | 7050/A97050 | A7050 | AI Zn6CuMgZr | EN AW-7050/AI Zn6CuMgZr | |||||
138 | GB/T 3190-1996 | AA/UNS | JIS H4080-1999 JIS H4000-1999 | DIN 1725.1-1986/W-Nr. | BS 1470-1988 | NF A50-411 NF A50-451 | ГOCT 4785-1974 | IS733-2001 IS737-2001 | ISO 209.1-1989 | EN 573-3-1994 |
139 | 7475 | 7475/A9475 | AI Zn5.5MgCu(A) | EN AW-7475/AI Zn5.5MgCu(A) | ||||||
140 | GB/T 3190-1996 | AA/UNS | ISO 209.1-1989 | EN 573-3-1994 | ||||||
141 | 7010 | AI Zn6MgCu | EN AW-7010/AI Zn6MgCu | |||||||
142 | AA | ISO 209.1-1989 | EN 573-3-1994 | |||||||
143 | 7012 | EN AW-7012/AI Zn6Mg2Cu | ||||||||
144 | AA | EN 573-3-1994 | ||||||||
145 | 7049A | 7049A(A-Z8GU) | AI Zn8MgCu | EN AW-7049A/AI Zn8MgCu | ||||||
146 | AA | NF A50-411 NF A50-451 | ISO 209.1-1989 | EN 573-3-1994 | ||||||
147 | 7178 | AI Zn7MgCu | EN AW-7178/AI Zn7MgCu | |||||||
148 | AA | ISO 209.1-1989 | EN 573-3-1994 |
Our customers are from all over the world, we welcome customers to our company to visit and communicate.
For our products' quality and service's level has been a great help.
FAQ:
Q1:How long time is the shortest delivery?
A1:For stock material,the delivery time is just 3-5 working days.
And for customized product,it will takes 25-35 working days based on different size and quantity.
Q2:Can you supply the sample?Does it free or not?
A2:For partial materials,we can supply the sample free(without the freight charge).
If you want to know more details,please contact our sales online.
Q3:What's the terms of payment?
A3:We can accept T/T,100% irrevocable LC at sight,Western Union,etc,
Q4:How to ensure the quality?
A4: We can supply QC,such as MTC,SGS, UT Certificate,etc.
Besides,we have Trade Assurance Amount from Alibaba Group.
If our quality is unapproved,we need and will refund full payment to customers
Q4.How can we get your price ?
We need below information to quote for you:
1. Product Name
2. Standard
3. Material Grade (Chemical Composition)
4. Dimension
5. Quantity
6. The Drawing for Special Parts